Mould sampling for indoor air quality

IRIS laboratory team · NVLAP accredited · 12:15

Free

Indoor and outdoor spore trap pairs, why the outdoor control decides the whole result, and how long to run the pump.

Sign in to save your place and download the material.

Airborne spores are the exposure pathway, so air sampling tells you what occupants are actually breathing. Use it for a musty odour, occupant symptoms or an IAQ complaint with no visible growth, for baseline comparisons, and for post-remediation clearance.

The method

ItemDetail
MethodSpore trap, ASTM D7391-20
AccreditationAIHA-LAP EMLAP 173498
MediaAir-O-Cell cassette or equivalent
Turnaround3 to 5 business days

On site

  1. Attach the cassette to the pump in the breathing zone.
  2. Run 10 to 25 litres of air through each cassette.
  3. For every cassette, record the air volume and the sample location on the COC.
  4. Plan for an outdoor reference. The lab compares indoor results with the outdoor reference where applicable, and clearance needs indoor spore levels comparable to outdoor.
Clearance after remediation needs both: air sampling to show no elevated spores, and a surface tape lift to show no residual growth.

What the report tells you

The certified report identifies fungal genera and gives spore counts. Genera IRIS commonly identifies include Cladosporium, Aspergillus/Penicillium, Stachybotrys, Chaetomium, basidiospores and Alternaria.

Sending samples

Spore trap cassettes need no refrigeration. Ship overnight with the COC inside, or drop off at 2333 US-22 West, Union, NJ, Monday to Friday before 4 PM ET. Kits from the lab include Air-O-Cell cassettes, tape lift slides, the COC form and a prepaid overnight FedEx label.

Start the mould COC, or download the mould COC (PDF).

Mould

Spore traps, swabs, tape lifts and bulk. Air and surface on one form.

Start this COC

Downloads

Downloads are behind sign-in.

Sign in to download

What you need for this test

Open in supplies
Mould starter kit KIT-MOLD-START
Pump, 25 Air-O-Cell cassettes, swabs, Bio-Tape and a pad of COC forms.
Air-O-Cell spore trap cassette SPORE-AOC
The standard non-viable spore trap. 15 L/min for 5–10 minutes.
High-volume air sampling pump PUMP-HV-1
1–15 L/min, 8-hour battery, constant flow. The workhorse for clearance and personal sampling.
Build a request