No signal. What you type is saved on this phone and sends when you are back in range.
IRIS Environmental Laboratories Client portal Sign in

← Knowledge base

Recording soon Rod is filming this one. Until it is up, the written guide below has the essentials.

Respirable crystalline silica: personal sampling on site

IRIS laboratory team · NIOSH 0600 / 7602 · 12:00

Free

Cyclone setup, calibrating at 2.5 L/min, full-shift sampling and what the OSHA action level means for your client.

Sign in to save your place and download the material.

Personal breathing zone (PBZ) sampling is how you document worker exposure to respirable crystalline silica under OSHA 1926.1153. Use it when workers cut, drill or jackhammer concrete or masonry, or do other OSHA Table 1 tasks such as abrasive blasting and tuck-pointing.

Talk to the lab first

Before you sample, tell the lab your task type, matrix and regulatory requirement. They confirm the method, filter media and sampling duration in one reply. Contact the lab or email support@irislaboratories.com.

On site

  • Clip the sampler to the worker's lapel, in the breathing zone.
  • Record each sample on the silica COC.

The limits your result is compared with

LimitValue
OSHA PEL, 8-hour TWA50 µg/m³
OSHA Action Level, 8-hour TWA25 µg/m³
NIOSH REL0.05 mg/m³
ACGIH TLV0.025 mg/m³

Method and turnaround

PBZ samples are analysed by NIOSH 7500 / 7602 (IR). The certified report, COC and PDF arrive by email in 3 to 5 business days, in a format accepted for OSHA submissions.

Sending samples

Drop off at 2333 US-22 West, Union, NJ 07083, Monday to Friday before 4:00 PM ET, or ship overnight with the COC inside the package.

Need the silica content of a material before work starts? That is a bulk analysis (NIOSH 9002 / EPA 600), not a PBZ sample.

For pre-demolition jobs, pair bulk analysis to characterise the hazard with PBZ sampling to document worker exposure during and after the work.

Download the silica COC (PDF).

Chain of custody

Pick the form that matches your test.

Start this COC

Downloads

Downloads are behind sign-in.

Sign in to download

What you need for this test

Open in supplies
Low-flow personal sampling pump PUMP-LV-1
5–500 mL/min for sorbent tubes and personal monitoring. Belt clip included.
Aluminium cyclone, respirable CYCL-ALU
Respirable size-selective sampling at 2.5 L/min.
PVC cassette, 37 mm, 5 µm CASS-PVC-37
Respirable dust and metals by NIOSH 0600 and 7602.
Primary flow calibrator PUMP-CAL-1
Calibrate before and after every run. Required for defensible air results.
Build a request

Related topics