Field sampling by IRIS (FiberGuard)
IRIS Environmental Laboratories · 2 min read
When to have IRIS FiberGuard field professionals sample asbestos on site, what they bring, what the results cover, and what to send with your inquiry.
Sign in to save your place and download the material.
IRIS FiberGuard™ is the lab's on-site asbestos sampling service. Certified field professionals come to your site, collect the samples and keep the chain of custody, and the lab runs PCM air, AHERA clearance and bulk PLM under NJ NELAP, NY ELAP #12738 and NVLAP 600211-0.
IRIS does not compete with the contractors and consultants who send it work. The lab runs the samples, and you keep the client relationship.
When to call FiberGuard
- A pre-demolition ACM survey is required. NESHAP mandates a survey before any demolition.
- A school needs post-abatement AHERA clearance. TEM clearance is required before reoccupancy.
- Workers are disturbing suspect material. OSHA 1926.1101 requires PCM air monitoring.
- You are renovating a pre-1980 building and need to identify ACM before work begins.
- Demolition waste needs classifying. NY ELAP analysis is required before licensed disposal.
- There is litigation or an insurance dispute, and you need a defensible chain-of-custody PLM and TEM report.
What they bring
- PCM cassettes and a sampling pump, for NIOSH 7400 fibre counting
- TEM air cassettes for AHERA clearance (40 CFR 763 App. A)
- Bulk sample containers and tools, taking a 1 to 2 cm² core per location
- An aggressive sampling setup (leaf blower and fan) for AHERA clearance
- Decontamination between locations: HEPA vacuum, wet wipe and a PPE change
- A chain-of-custody form that meets NJ NELAP, NY ELAP and NVLAP requirements
What the results tell you
| Result | Reported as |
|---|---|
| Airborne fibre count | f/cc, against the OSHA PEL of 0.1 f/cc TWA and the action level |
| AHERA clearance | TEM s/mm², with PASS or FAIL |
| ACM in bulk | % asbestos by mineral type |
| Non-friable NOB | Quantified under NY ELAP Item 198.6 |
| Waste classification | Friable and non-friable, for disposal documentation |
| NESHAP RACM | Bulk PLM result that drives EPA demolition notification |
How to request it
Send a sampling inquiry from the FiberGuard page with:
- the site address
- the property type
- the material you suspect
- the building's age
- any prior testing
The lab responds within one business day.
Other field services
For lead, IRIS can coordinate field sampling or send a self-collection kit. For VOCs, a certified field professional runs the on-site screening. Contact the lab or email support@irislaboratories.com.
Chain of custody
Pick the form that matches your test.
Start this COCDownloads
Downloads are behind sign-in.
Sign in to download