No signal. What you type is saved on this phone and sends when you are back in range.
IRIS Environmental Laboratories Client portal Sign in

← Knowledge base

PFAS testing

IRIS Environmental Laboratories · 2 min read

Free

Three PFAS panels run through accredited partner labs: which panel fits your site, the 2024 EPA drinking water limits, and the collection rules that keep samples clean.

Sign in to save your place and download the material.

IRIS runs PFAS testing through accredited partner laboratories. You order the kit and send samples through IRIS.

Pick the panel

PanelMethodMatrixTurnaround
PFAS-8, 8 compoundsEPA 537.1Drinking water5 to 7 business days
PFAS-14, 14 compoundsEPA 533Drinking water5 to 7 business days
PFAS-24, 24 compoundsEPA 8327Groundwater, surface water, wastewater, leachate7 to 10 business days
  • School, office or municipal water, SDWA/EPA compliance baseline: PFAS-8.
  • Near a chemical plant, an airport, or a known GenX or short-chain release: PFAS-14, which captures short-chain compounds and GenX that 537.1 misses.
  • Phase II ESA, groundwater monitoring or industrial discharge (NPDES): PFAS-24.
  • AFFF (firefighting foam) impacted site: PFAS-24, for the widest compound coverage.

2024 EPA drinking water MCLs

CompoundMCL
PFOA4 ppt
PFOS4 ppt
PFNA10 ppt
PFHxS10 ppt
HFPO-DA (GenX)10 ppt
PFBSCombined hazard index

ppt means parts per trillion.

Collection rules

PFAS sampling has strict protocols. Follow them exactly.

Use:

  • lab-supplied HDPE or polypropylene containers
  • nitrile gloves, changed between every sample
  • one field blank per sampling event
  • a trip blank that travels with the samples from the lab to the field and back

Do not use:

  • Teflon (PTFE) tubing, caps or fittings, which leach PFAS into the sample
  • standard lab glass containers
  • latex gloves
  • tap water as a field blank
  • containers that have not been pre-cleaned and certified by the lab

Shipping

Complete the COC with site information, matrix and requested analysis before you ship. Ship overnight with ice packs, so samples arrive refrigerated at 4°C. Do not ship warm or at ambient temperature. Turnaround starts on the date the lab receives the samples.

Every kit includes pre-certified HDPE containers, COC forms, a prepaid FedEx overnight label and a sampling instruction card. Reports come by email in PDF and Excel, compared with the applicable EPA MCLs and action levels.

To order a kit or choose a panel, contact the lab or email support@irislaboratories.com.

Chain of custody

Pick the form that matches your test.

Start this COC

Downloads

Downloads are behind sign-in.

Sign in to download

What you need for this test

Open in supplies
Reusable gel ice pack COOL-ICE
Water microbiology must arrive at or below 10 °C. Freeze overnight before use.
Insulated shipping cooler, 12 L COOL-BOX
Sized for overnight courier. Holds 12 bottles and two ice packs.
Build a request